Description: XH-M452 Digital Temperature & Humidity Controller

XH-M452 M452 Thermostat Temperature Humidity Control Thermometers Hygr-ometer Controller Module DC 12V LED Digital Display Dual Output Incubator Temperature Sensor NTC Probe & Dual Relay CityTech BD 

Digital Temperature and Humidity 12VDC Controller is capable of maintaining humidity and temperature. The module works at 12VDC power. The module has separate 220VAC 10A Relay outputs for Heater and Humidity Generator (External Fan, and Humidifier). CityTech BD 

  • Application scenario: control cabinet constant temperature and humidity control, incubation and breeding temperature control, printing plant.
  • The two relays are separately controlled, one way to control the temperature, another way to control the humidity.
  • If you do wrong operation ,it will return to detect temperature display automatically after 5 seconds .
  • Set the temperature – : Normal display mode, long press – button for 3 seconds, stop numerical flashing temperature, press the + / – key to set value.
  • Restore the factory Settings: At the same time long press temperature, and humidity + key for 3 seconds, digital display, 888, 888.

CityTech BD CityTech BD CityTech BD CityTech BD CityTech BD CityTech BD CityTech BD 

Specifications:

  • Model: XH-M452
  • Style: Exposed PCB
  • Display Type: Digital
  • Power Supply: DC 12V
  • Temperature Measurement Range: -40~120℃
  • Humidity Range:0~100%RH
  • Control Precision:0.1℃ 0.1%RH
  • Test Probe: Integrated Sensor
  • Test Probe Cable Length: ~90cm
  • Output: 10A delay CityTech BD CityTech BD 

Temperature Control: CityTech BD 

  • Set the temperature + :Normal display mode, long press the + key for 3 seconds, start temperature numerical flashing, press the + / – key setting values, wrong operation after 5 seconds, automatically return to detect temperature display
  • Set the temperature – :Normal display mode, long press – button for 3 seconds, stop numerical flashing temperature, press the + / – key set value
  • Restore the factory Settings :At the same time long press temperature, and humidity + key for 3 seconds, digital display, 888, 888
  • Set the start temperature: Long press the + key, start the flashing temperature, set start temperature by + / – key
  • Set Stop temperature: long press – button, stop flashing temperature, set stop temperature by + / – key

Humidity Control:

  • Set to start humidity: long press the + key, start the humidity value flashing, set by + / – key launch humidity value
  • Set stop humidity: long press – to stop humidity value, set by + / – key to stop the humidity value
  • Fault code: display LLL mean the sensor fault
  • Display HHH mean Test temperature exceed the range of measurement CityTech BD 

Applications:

  • Indoor Room Temperature and Humidity Control
  • Humidity and Temperature controller for Controlled Temperature sheds
  • Food and Beverage temperature and Humidity controller
  • Temperature and Humidity controller for Health Care applications
  • Temperature and Humidity controller for Incubators CityTech BD 

Package Include:

  • 1 x XH-M452 Digital Temperature & Humidity Controller

Review

Write a review

Note: HTML is not translated!
Bad Good