HW-633 DC 6V-60V Charger Module Voltage Over-Discharge Lithium Battery Protection Board digital battery over-discharge protection switch is specially designed for 12-36V lithium and lead-acid batteries.
This is a low voltage protection module that comes with an on-board momentary push button to set the low voltage disconnect parameter, when the battery voltage reaches the setting values, the module will disconnect the load automatically to avoid the battery from over-discharging to prolong the battery lifetime. CityTechBD
Product Images are shown for illustrative purposes only and may differ from the actual product. CityTechBD
Note: Relay brand may vary from actual product as our stock rotates.
Features:
- HW-633 control board Automatic power-off when full charged Intelligent, Power Saving, Safe Suitable for 12-24V Storage Battery
- Battery application: Lead-acid batteries, Solar cells, new energy batteries, Car battery, electric car battery, Lithium-ion battery, polymer battery
- Made of ABS plastic and metal, durable and tough
- Automatic power-off when full charged. CityTechBD
Applications:
- Lead-acid batteries
- Solar cells
- New energy batteries
- Car battery
- Electric car battery
- Lithium-ion battery
- polymer battery
| General Specification |
| Type | Voltage Regulator |
| Model Number | HW-633 |
| Model | HW-633 |
| Color | blue |
| Material | ABS + Metal |
| Operating Temperature | -40-+85 |
| Supply Voltage | 6-60V |
| Input Voltage | DC 6-60V |
| Display Accuracy | 0.1V |
| Control Accuracy | 0.1V |
| Output Type | Direct output |
| Voltage Tolerance | ±0.1V |
| Apply For | 6-60V MAX 80V battery |
| Size | 81.5 x 54.5 x 24mm(3.21*2.15*0.94in) |
| Shipment Weight | 0.020 kg |
| Shipment Dimensions | 10 × 7 × 3 cm |
Please allow 5% measuring deviation due to manual measurement.
Documentation:
In the state of setting the voltage value, the start button plays the role of the up button, and the stop button acts as the down button.
How to use:
- Set the startup voltage: under the normal display voltage state, press the start voltage button once to display the start charging voltage. Press and hold the start button for 3 seconds, the digit flashes, and the start charging voltage value is set by the start and stop buttons.
- Set the stop voltage: In the normal display voltage state, press the stop voltage button once to display the stop charging voltage. Long press the stop button for 3 seconds, the digit flashes, and the charging voltage value is stopped by the start and stop buttons.
- Restore factory settings: press and hold the start / stop button at the same time when the power is on, the digital display 888, that means restore the factory settings. CityTechBD
Package Includes:
1 x Digital display Lead acid Battery Charge Control Module